Continuous
Corrugated Welded Armor
MV-90
Power Cable with Ground
EPR/PVC Shielded
Type MC 15kV
100% and 133% Insulation
|
|
| A
P P L I C A T I O N S |
1.
2.
3.
4.
5.
6. |
Used in place
of wire in conduit
Feeder and branch circuits
Industrial power distribution systems
Wet or dry locations
Direct burial
Indoors and Outdoors |
|
7.
8.
9.
10.
11. |
Substations,
cogeneration and other industrial facilities
Can be used in cable tray
Can be encased in concrete
Class I, II and III Divisions 1 and 2 hazardous locations
Can be installed in metal racks and troughs |
|
| S
P E C I F I C A T I O N S |
1.
2.
3.
4.
5.
6.
7. |
Conductor:
Stranded soft-drawn bare copper
Conductor Shield: Extruded Semi-conducting EPR
Insulation: Ethylene propylene rubber (EPR)
Ground Wire: Stranded soft-drawn bare copper
Shield: Copper tape
Cabling: Insulated conductors and ground wire are
cabled with fillers and a binder tape overall
Armor: Impervious, continuous corrugated aluminum
sheath |
|
8.
9.
10.
11. |
Jacket:
Red sunlight resistant, low-temperature polyvinyl chloride
(PVC)
Temperature: -40°C to 90°C wet or dry
Voltage: 15000 Volts 100% & 133%
Industry Approvals:
UL Type MC
UL 1072
UL Type MV-90
AEIC CS-6
IEEE 383 flame test (70,000 Btu/hr)
ICEA flame test (210,000 Btu/hr)
IEC 502, 540 and 332-3
CSA Listed C68.3 |
|
Part
Number |
Size
AWG
/MCM |
No.
of
Cond. |
Ground
Cond. |
Insul.
Thick.
in. |
Core
O.D.
in. |
Armor
O.D.
in. |
Jacket
Thick.
in. |
Overall
O.D.
in. |
Approx.
Weight
lbs/Mft |
| 100%
Insulation Level |
| 05-CK-3893 |
2 |
3 |
6 |
.175 |
1.61 |
1.96 |
.060 |
2.05 |
2472 |
| 05-CK-3993 |
1 |
3 |
4 |
.175 |
1.68 |
2.01 |
.060 |
2.15 |
2864 |
| 05-CK-4093 |
1/0 |
3 |
4 |
.175 |
1.78 |
2.10 |
.060 |
2.24 |
3295 |
| 05-CK-4193 |
2/0 |
3 |
4 |
.175 |
1.88 |
2.19 |
.060 |
2.36 |
3665 |
| 05-CK-4393 |
4/0 |
3 |
3 |
.175 |
2.09 |
2.45 |
.075 |
2.61 |
4785 |
| 05-CK-4493 |
250 |
3 |
3 |
.175 |
2.19 |
2.58 |
.075 |
2.74 |
5350 |
| 05-CK-4893 |
350 |
3 |
2 |
.175 |
2.45 |
2.85 |
.075 |
3.01 |
7257 |
| 05-CK-5393 |
500 |
3 |
1 |
.175 |
2.71 |
3.16 |
.085 |
3.34 |
9597 |
| 05-CK-6093 |
750 |
3 |
1/0 |
.175 |
3.12 |
3.67 |
.085 |
3.85 |
12643 |
| 133%
Insulation Level |
| 05-CL-3893 |
2 |
3 |
6 |
.220 |
1.82 |
2.19 |
.060 |
2.32 |
3147 |
| 05-CL-3993 |
1 |
3 |
4 |
.220 |
1.88 |
2.23 |
.060 |
2.36 |
3404 |
| 05-CL-4093 |
1/0 |
3 |
4 |
.220 |
1.96 |
2.32 |
.075 |
2.48 |
3674 |
| 05-CL-4193 |
2/0 |
3 |
4 |
.220 |
2.07 |
2.45 |
.075 |
2.61 |
4219 |
| 05-CL-4393 |
4/0 |
3 |
3 |
.220 |
2.27 |
2.67 |
.075 |
2.83 |
5558 |
| 05-CL-4493 |
250 |
3 |
3 |
.220 |
2.39 |
2.80 |
.075 |
2.96 |
6424 |
| 05-CL-4893 |
350 |
3 |
2 |
.220 |
2.61 |
3.07 |
.085 |
3.30 |
7975 |
| 05-CL-5393 |
500 |
3 |
1 |
.220 |
2.87 |
3.41 |
.085 |
3.64 |
10406 |
| 05-CL-6093 |
700 |
3 |
1/0 |
.220 |
3.30 |
4.02 |
.085 |
4.20 |
14138 |
|
|
JCH Wire & Cable... striving to exceed
customer expectations for quality, service, and value